Calculators
Determining the transport index (TI)
From the dose rate measured 1 m from the package surface, determines the transport index, the package category (WHITE-I, YELLOW-II, YELLOW-III) and the label to attach. Each step follows clause 4.23 of the regulations.
Size adjustment factor (Table 3)
Applies only to unpackaged LSA-I and SCO-I consignments and to large freight containers and tanks.
Type a value into a field and the meter in the drawing shows it.
- Radioactive material
- Shielding (lead)
- Package
The metre is measured from the package's outer surface, not from the material inside. Drawn to scale: the package is about 45 cm.
On the surface (P) — sets the category
no reading entered
At 1 m — gives the index
no reading entered
How the index is calculated (4.23)
- 1. Measured value—at 1 m, 4.23 (1)
- 2. × 100—4.23 (2)
- 3. × 1—No size factor — unchanged
- 4. round up—4.23 (5)
Enter the dose rate to see the index, category and label.
Category table (Table 4)
| Transport index | Surface level P | Category | |
|---|---|---|---|
| mSv/h | µSv/h | ||
| 0 | ≤ 0.005 | ≤ 5 | WHITE-I |
| 0 < TI ≤ 1 | > 0.005 – 0.5 | > 5 – 500 | YELLOW-II |
| 1 < TI ≤ 10 | > 0.5 – 2 | > 500 – 2000 | YELLOW-III |
| 10 < TI | > 2 – 10 | > 2000 – 10000 | YELLOW-III (special arrangement) |
Source: Regulations for the Safe Transport of Radioactive Material, 4.23, 4.29 and Tables 3 and 4. This calculation is an aid; for actual shipments rely on the regulations themselves.