Your Annual Radiation Dose
1Medical exams
- Chest X-ray0.1 mSv each
- Dental X-ray0.005 mSv each
- Panoramic dental X-ray0.025 mSv each
- Mammography0.28 mSv each
- Lumbar spine X-ray1.4 mSv each
- CT of the brain1.6 mSv each
- CT of the chest6.1 mSv each
- CT of the abdomen and pelvis7.7 mSv each
- Coronary CT angiography8.7 mSv each
- PET/CT (whole body)22.7 mSv each
CT: computed tomography.
2Flights
3Radon at home(optional)
Your annual radiation dose
3.3mSv/y
Effective dose per year
100% of it is natural radiation.
Every calculation runs in your browser.
What it is made of
- Radon and thoron (breathed in)· World average1.8 mSv
- Cosmic radiation· Mongolia0.55 mSv
- Radiation from soil and rock· World average0.40 mSv
- Food and water· World average0.50 mSv
- Medical exams0 mSv
- Flights0 mSv
For comparison
- Natural radiation, world average3.0 mSv
- Natural radiation, Mongolia3.3 mSv
- Your annual radiation dose3.3 mSv
The dose limit for the public
“The dose limit for the general public shall not exceed 1 mSv a year. Normal natural background radiation and medical (therapeutic or diagnostic) exposure are not included.”Radiation Safety Norms, 5.3 (our translation; the Mongolian text is official) →
Method and sources
Natural radiation doses are from the 2024 report of the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). For cosmic rays Mongolia's figure is 0.5-0.6 mSv (figure VII): twice the world average of 0.3 mSv, because people here live high above sea level. The report has no Mongolian figure for the other three pathways, so the world averages are used (table 15).
If you enter a radon measurement, it replaces the 1.3 mSv that the world average of 50 Bq/m³ gives: dose = radon (Bq/m³) × 0.8 × 8760 h × (0.4 × 9 + 0.18) nSv/(Bq·h/m³) (§144).
Doses per exam are typical adult values (RadiologyInfo.org, RSNA and ACR, reviewed 15 April 2025). Children's doses, and doses from a given machine or protocol, can differ.
6 µSv per hour of flight: the top of UNSCEAR's range of 1-6 µSv/h (§203). Mongolia lies at 42-52° N, so the top value is used rather than understate the dose.
This is an estimate and does not replace personal dose monitoring. If you work with radiation, take part in individual monitoring of occupational exposure. Service providers →