Radiation Dose Rate Calculator
1Radionuclide
Common sources
Or choose from 522 isotopes
Co-60 · T½ 5.271 y · computed from 11 gamma lines · 1 GBq at 1 m gives 354 µSv/h
2Activity and distance
Filled in as an example: 1 Ci (37 GBq) at 1 m. Enter your own values.
Dose rate
13.1mSv/h
H*(10), ambient dose equivalent rate
Co-60 · 37 GBq · at 1 m
= 13,100 µSv/h · if continuous, 115 Sv a year
Against the nearest level below it in the rules
1.31 times higher
Package surface (exclusive use) · 10 mSv/h
How high is this?
- Your result13.1 mSv/h
- Package surface (exclusive use)Transport Regulations 4.28 →10 mSv/h
- Package surface (normal transport)Transport Regulations 4.27 →2 mSv/h
- 2 m from the surface of a vehicleTransport Regulations 4.66 →100 µSv/h
- Driver and operator seat while a source is carriedSafety Standards 6.2 →10 µSv/h
- 1 m from a fixed nuclear gaugeSafety Standards 6.1 →3 µSv/h
- Ambient dose rate above which the public is informedEmergency plan 3.8 →0.6 µSv/h
- Natural external radiation (world average)UNSCEAR 2024 ↗0.08 µSv/h
Each limit applies in its own situation (where it is measured, what activity). Read the conditions in the clause.
Distance and dose rate
Drag the slider to walk the person away from the source: doubling the distance cuts the dose rate to a quarter.
Fall-off with distance
Both axes logarithmic. Move the pointer over the chart to read it off.
How long, and how much dose
Dose received
105 mSv
8 h × 13.1 mSv/h
- Annual limit for the public, 1 mSv⚠ Exceeded · 10,500% of the limit
reached in 4.58 min
- Annual limit for workers, 20 mSv⚠ Exceeded · 525% of the limit
reached in 1.53 h
How far away
The distance at which the dose rate falls to the level chosen.
Target dose rate
at 36.2 m
Unshielded, by the inverse-square law.
Dose limits
Radiation Safety Standards →The maximum permitted annual doses. Each dot is one limit: the left one for the public, the right one for radiation workers. The dose from your calculation above is marked in orange on the effective-dose row.
The activity can be brought up to date with the Half-Life Calculator.
How the number is calculated
Where the figure on this page comes from, and what it leaves out.
Inverse-square law: doubling the distance cuts the dose rate to a quarter.
Notation
- Ambient dose equivalent rate
- µSv/h
- Dose rate constant, computed from each isotope's gamma spectrum
- µSv·m²/(h·GBq)
- Source activity
- GBq
- Distance from the source to the point of measurement
- m
How the Γ constant is derived
- 1Gamma lines
The energies Eᵢ and intensities Iᵢ of the photons each isotope emits.
Source: IAEA Live Chart of Nuclides
- 2Absorption in air
The mass energy-absorption coefficient (µen/ρ)air at each Eᵢ, by logarithmic interpolation.
- 3Conversion to dose
Air kerma is multiplied by the h*(10)/Ka(Eᵢ) coefficient to give ambient dose equivalent.
Source: ICRP Publication 74
- 4Sum
All lines are summed and divided by 4π. Metastable states are filtered by the parent's excitation energy, so lines of other states are excluded.
Source: computed for 522 isotopes
What is not included
- A point source is assumed: the source must be much smaller than the distance. Close in, where d is comparable to the source size, the value comes out far too high.
- Self-absorption in the source and its encapsulation is not included.
- Shielding (lead, concrete, water) is not included. With shielding the real value is lower.
- Attenuation in air is not included: within a few tens of metres it is negligible.
- Only gamma and X-ray photons are counted. Beta, neutron and bremsstrahlung radiation are excluded.
Check against published values
At 1 m from 1 GBq, in µSv/h.
| Isotope | Ours | Reference |
|---|---|---|
| Co-60 | 354.4 | 354 |
| Cs-137 | 92.9 | 92.7 |
| I-131 | 66.1 | 66 |
| Ir-192 | 140.2 | 139 |
Reference: 1 cm dose-equivalent rate constants, Japan Radioisotope Association, Isotope Handbook, 11th edition (as quoted in a 2016 report of Japan's Fire and Disaster Management Agency).
Note. This calculator is for training and preliminary assessment. For official measurements, workplace planning and licence documentation, rely on calibrated dosimetry.