An independent information and reference site
Calculators

Radiation Dose Rate Calculator

Computes the dose rate at a distance from a point gamma source with the inverse-square law (H = Γ · A / d²), and sets the result straight against the limits in Mongolia's rules and the annual dose limits.

1Radionuclide

Common sources

Or choose from 522 isotopes

Co-60 · T½ 5.271 y · computed from 11 gamma lines · 1 GBq at 1 m gives 354 µSv/h

2Activity and distance

Filled in as an example: 1 Ci (37 GBq) at 1 m. Enter your own values.

Dose rate

13.1mSv/h

H*(10), ambient dose equivalent rate

Co-60 · 37 GBq · at 1 m

= 13,100 µSv/h · if continuous, 115 Sv a year

Against the nearest level below it in the rules

1.31 times higher

Package surface (exclusive use) · 10 mSv/h

How high is this?

  1. Your result13.1 mSv/h
  2. Package surface (exclusive use)Transport Regulations 4.28 →10 mSv/h
  3. Package surface (normal transport)Transport Regulations 4.27 →2 mSv/h
  4. 2 m from the surface of a vehicleTransport Regulations 4.66 →100 µSv/h
  5. Driver and operator seat while a source is carriedSafety Standards 6.2 →10 µSv/h
  6. 1 m from a fixed nuclear gaugeSafety Standards 6.1 →3 µSv/h
  7. Ambient dose rate above which the public is informedEmergency plan 3.8 →0.6 µSv/h
  8. Natural external radiation (world average)UNSCEAR 2024 ↗0.08 µSv/h

Each limit applies in its own situation (where it is measured, what activity). Read the conditions in the clause.

Distance and dose rate

Drag the slider to walk the person away from the source: doubling the distance cuts the dose rate to a quarter.

13.1 mSv/h1 m10 cm1 m10 m100 m

Fall-off with distance

Both axes logarithmic. Move the pointer over the chart to read it off.

1 m → 13.1 mSv/h1 µSv/h100 µSv/h10 mSv/h1 Sv/h10 cm1 m10 m100 mTarget: 36.2 m

How long, and how much dose

Dose received

105 mSv

8 h × 13.1 mSv/h

  • Annual limit for the public, 1 mSv⚠ Exceeded · 10,500% of the limit

    reached in 4.58 min

  • Annual limit for workers, 20 mSv⚠ Exceeded · 525% of the limit

    reached in 1.53 h

Radiation Safety Standards 5.1 →

How far away

The distance at which the dose rate falls to the level chosen.

Target dose rate

at 36.2 m

Unshielded, by the inverse-square law.

The maximum permitted annual doses. Each dot is one limit: the left one for the public, the right one for radiation workers. The dose from your calculation above is marked in orange on the effective-dose row.

PublicRadiation workersYour computed doseTypical reference dose (not a limit)mSv/y, logarithmic axis
Chest X-rayNatural backgroundCT (abdomen)
Effective dose (whole body)5.1 →
public 1 mSv/yworkers 20 mSv/yYour dose: 105 mSv (8 h)Averaged over 5 consecutive years. In any single year, workers may not exceed 50 mSv and the public 5 mSv.
Lens of the eye5.1 →
public 15 mSv/yworkers 20 mSv/y
public 50 mSv/yworkers 500 mSv/y
Hands and feet5.1 →
public 50 mSv/yworkers 500 mSv/y
0.11101001000
Women under 451 mSv / monthEquivalent dose at the surface of the lower abdomen.Safety Standards 5.2 →
Carers of patients5 mSv / yearDuring X-ray or radiological treatment (not sector workers).Safety Standards 13.1 →
Patient discharge3 µSv/hGamma dose rate measured at 1 m.Safety Standards 13.2 →
Exemption level10 µSv / yearEffective dose to the public from an exempted source or practice.Safety Standards 10.2 →

The activity can be brought up to date with the Half-Life Calculator.

How the number is calculated

Where the figure on this page comes from, and what it leaves out.

H∗(10)=ΓH Ad2H^{*}(10) = \frac{\Gamma_{\mathrm{H}}\,A}{d^{2}}

Inverse-square law: doubling the distance cuts the dose rate to a quarter.

Notation

H∗(10)H^{*}(10)
Ambient dose equivalent rate
µSv/h
ΓH\Gamma_{\mathrm{H}}
Dose rate constant, computed from each isotope's gamma spectrum
µSv·m²/(h·GBq)
AA
Source activity
GBq
dd
Distance from the source to the point of measurement
m

How the Γ constant is derived

ΓH=14π∑iIi Ei(μenρ) ⁣air ⁣(Ei) h∗(10)Ka(Ei)\Gamma_{\mathrm{H}} = \frac{1}{4\pi}\sum_{i} I_i\,E_i\left(\frac{\mu_{\mathrm{en}}}{\rho}\right)_{\!\mathrm{air}}\!(E_i)\,\frac{h^{*}(10)}{K_{\mathrm{a}}}(E_i)
  1. 1
    Gamma lines

    The energies Eᵢ and intensities Iᵢ of the photons each isotope emits.

    Source: IAEA Live Chart of Nuclides

  2. 2
    Absorption in air

    The mass energy-absorption coefficient (µen/ρ)air at each Eᵢ, by logarithmic interpolation.

    Source: NIST X-Ray Mass Attenuation Coefficients

  3. 3
    Conversion to dose

    Air kerma is multiplied by the h*(10)/Ka(Eᵢ) coefficient to give ambient dose equivalent.

    Source: ICRP Publication 74

  4. 4
    Sum

    All lines are summed and divided by 4π. Metastable states are filtered by the parent's excitation energy, so lines of other states are excluded.

    Source: computed for 522 isotopes

What is not included

  • A point source is assumed: the source must be much smaller than the distance. Close in, where d is comparable to the source size, the value comes out far too high.
  • Self-absorption in the source and its encapsulation is not included.
  • Shielding (lead, concrete, water) is not included. With shielding the real value is lower.
  • Attenuation in air is not included: within a few tens of metres it is negligible.
  • Only gamma and X-ray photons are counted. Beta, neutron and bremsstrahlung radiation are excluded.

Check against published values

At 1 m from 1 GBq, in µSv/h.

IsotopeOursReference
Co-60354.4354
Cs-13792.992.7
I-13166.166
Ir-192140.2139

Reference: 1 cm dose-equivalent rate constants, Japan Radioisotope Association, Isotope Handbook, 11th edition (as quoted in a 2016 report of Japan's Fire and Disaster Management Agency).

Note. This calculator is for training and preliminary assessment. For official measurements, workplace planning and licence documentation, rely on calibrated dosimetry.